Labcycler Gradient

Labcycler Gradient

The Labcycler Gradient (011-101) has the same technical features as its brother Labcycler Basic has. In addition, the Gradient function is active which can be applied by Thermoblock 48 (012-102), Thermoblock 96 (012-103), Thermoblock 96 alu (012-108), and Thermoblock 384. Temperature gradients from 8 to 24 zones are possible to determine the optimal annealing temperature. The Labcycler Gradient is also available as an IVD version and thus complies with the European Directive for in vitro diagnostics (011-105). The Thermoblock 96 and 384 can be applied for high through put. The Triple Block can be used in the Labcycler Gradient without gradient function. The package Labcycler Gradient with Thermoblock 96 and Triple Block should be an interesting tool for all standard laboratories.

Ordering Information

The Labcycler Gradient must be ordered in combination with one Thermoblock. Additionally, a second or more Thermoblocks can be ordered because the system has a quick-block-changing system. A Thermoblock can be changed in a few seconds. The Labcycler Gradient works at all global line voltages (85-265 V).

Product Order Number
Labcycler Gradient 011-101
Thermoblock 48, silver
012-102
Thermoblock 96, silver 012-103
Thermoblock 384, silver 012-101

Triple Block

012-104

Passive Lids

012-201
In situ Block 012-107
Thermoblock 96 alu 100 012-108

Technical Data

Line voltage 85 V to 265 V, 50 to 60 Hz
Power consumption Maximum 350 W, standby 25 W
Noise Idle 38 dBA, typical 44 dBA, maximum 48 dBA
Display TFT illuminated colour display ¼ VGA, 5.7“ diagonal, 320 x 240 pixel, touchscreen
Heated Lid Programable: Pressure 0 to 120 N, temperature RT up to 110 °C
Dimension Length: 44 cm; width: 25 cm; height: 20 cm
Weight 11.8 kg
Keyboard Numeric and virtual keys
Languages English, German, Spanish & Chinese
Programs 680 standard programs, or at least 3000 steps, the last 16 program runs can be displayed any time, re-start function, programmed and manual pause
Password protection Configurable up to 64 users
Administration Administrator rights: Reading & writing
Copy function Intersystem-copy-function with Labcycler 48 & 192s, Labcycler Basic, and Labcycler Gradient
Gradient 40 °C, ± 20 °C from left to right
Temperature Minus 5.0 °C to 99.9 °C
Ramp rate 0.001 °C – 5.0 °C
Homogeneity ± 0.25 °C @ 55 °C, ± 0.4 °C @ 95 °C
De(In)crements Time: ± 99.99 s, temperature: ± 9.99 °C
Instant incubation Yes, e.g. at 0.0 °C, 26 °C, 37°C, and so on

Similar Products: Labcycler Basic

Global Distributors

Please use the button below to find your local dealer.

All Distributors