Labcycler Gradient

Labcycler Gradient

The Labcycler Gradient (011-101) has the same technical features as its brother Labcycler Basic has. In addition, the Gradient function is active which can be applied by Thermoblock 48 (012-102), Thermoblock 96 (012-103), Thermoblock 96 alu (012-108), and Thermoblock 384. Temperature gradients from 8 to 24 zones are possible to determine the optimal annealing temperature. The Labcycler Gradient is also available as an IVD version and thus complies with the European Directive for in vitro diagnostics (011-105). The Thermoblock 96 and 384 can be applied for high through put. The Triple Block can be used in the Labcycler Gradient without gradient function. The package Labcycler Gradient with Thermoblock 96 and Triple Block should be an interesting tool for all standard laboratories.

Ordering Information

The Labcycler Gradient must be ordered in combination with one Thermoblock. Additionally, a second or more Thermoblocks can be ordered because the system has a quick-block-changing system. A Thermoblock can be changed in a few seconds. The Labcycler Gradient works at all global line voltages (85-265 V).

ProductOrder Number
Labcycler Gradient011-101
Thermoblock 48, silver
012-102
Thermoblock 96, silver012-103
Thermoblock 384, silver012-101

Triple Block

012-104

Passive Lids

012-201
In situ Block012-107
Thermoblock 96 alu 100012-108

Technical Data

Line voltage85 V to 265 V, 50 to 60 Hz
Power consumptionMaximum 350 W, standby 25 W
NoiseIdle 38 dBA, typical 44 dBA, maximum 48 dBA
DisplayTFT illuminated colour display ¼ VGA, 5.7“ diagonal, 320 x 240 pixel, touchscreen
Heated LidProgramable: Pressure 0 to 120 N, temperature RT up to 110 °C
DimensionLength: 44 cm; width: 25 cm; height: 20 cm
Weight11.8 kg
KeyboardNumeric and virtual keys
LanguagesEnglish, German, Spanish & Chinese
Programs680 standard programs, or at least 3000 steps, the last 16 program runs can be displayed any time, re-start function, programmed and manual pause
Password protectionConfigurable up to 64 users
AdministrationAdministrator rights: Reading & writing
Copy functionIntersystem-copy-function with Labcycler 48 & 192s, Labcycler Basic, and Labcycler Gradient
Gradient40 °C, ± 20 °C from left to right
TemperatureMinus 5.0 °C to 99.9 °C
Ramp rate0.001 °C – 5.0 °C
Homogeneity± 0.25 °C @ 55 °C, ± 0.4 °C @ 95 °C
De(In)crementsTime: ± 99.99 s, temperature: ± 9.99 °C
Instant incubationYes, e.g. at 0.0 °C, 26 °C, 37°C, and so on

Similar Products: Labcycler Basic

Global Distributors

Please use the button below to find your local dealer.

All Distributors